MultiCam Boards Documentation > GRABLINK series Documentation > GRABLINK Full XR Handbook > I/O Ports Electrical Specifications > Chassis Ground/Signal Ground Interconnect

Chassis Ground/Signal Ground Interconnect

Chassis ground/Signal ground interconnect

The "Chassis ground" electrical net is connected to the "Signal ground" electrical net through a network as shown in the figure above. This prevents against significant voltages to be developed between the two nets.

Together with the cable shield and resistor, it provides an additional path for the (DC) return current of the camera power supply.

Notes