Event Signaling
When configured for event signaling usage, the output multiplexer is restricted to one position that selects the output of the event signal generator.
The generator is configured by means of SetSignal and ResetSignal.
SetSignal is a collection parameter that configures the multiplexer on the set branch of the SR flip-flop.
ResetSignal is a collection parameter that configures the multiplexer on the reset branch of the SR flip-flop.
All the multiplexers of the event signal generator exhibit the same set of events sources.
- Start and end of : channel activity, acquisition phase, acquisition sequence
- Rising and falling edges of Camera Link downstream control signals: FVAL, LVAl, DVAL
- Rising and falling edges of Camera Link upstream control signals: CC1, CC2, CC3, CC4
In addition, the multiplexer can be set to the position NONE ensuring that no more event are considered.
Note. When the set and reset condition are identical, the SR flip/flop toggles at every event.