PoCL OVP - Overvoltage Protection
Each PoCL controller integrates an "OverVoltage Protection circuit: the OVP.
The OVP clamps the output voltage in case of a defective external power supply.
PoCL OVP characteristics
Parameter |
Min |
Typ |
Max |
Units |
Output clamping voltage |
13 |
15 |
17 |
V |