Description
Type |
Integer |
Description |
Camera line repetition rate |
"Set" effect |
Sets the line rate |
"Get" effect |
Returns the line rate currently involved |
Classification
Class |
Channel |
Category |
Camera Timing |
Level |
Expert |
Identifiers
String |
LineRate_Hz |
C, C++ |
MC_LineRate_Hz |
.NET |
MC.LineRate_Hz |
Numerical |
705 |
This parameter is expressed in Hertz (s-1).
It declares the line rate, which is the repetition frequency of the video lines scanned and delivered by the camera feeding the channel.
This value is a performance figure often stated as is by the camera manufacturer.
For area-scan cameras, the line rate is usually under control of the camera itself.
In the special case of an area-scan camera receiving horizontal drive information from the frame grabber, the LineRate_Hz parameter expresses the recommended horizontal frequency to be applied to the camera.
For line-scan cameras, the line rate is usually under control of the frame grabber. In that case, the LineRate_Hz parameter declares the maximum line frequency the camera can accept.
In the special case of a line-scan camera controlling its own line timing, the LineRate_Hz parameter expresses the actual horizontal frequency set by the camera.
Values applicable to Grablink Full, Grablink Full XR, Grablink DualBase, Grablink Base
10 to 100000 Hz