LineRate_Hz

Picolo Picolo Junior 4 Picolo Pro 2 Picolo Pro 3 Picolo Tetra Picolo Tymo Picolo Alert Picolo Diligent

Description

Type

Integer

Description

Camera line repetition rate

"Set" effect

Sets the line rate

"Get" effect

Returns the line rate currently involved

Classification

Class

Channel

Category

Camera Timing

Level

Expert

Identifiers

String

LineRate_Hz

C, C++

MC_LineRate_Hz

.NET

MC.LineRate_Hz

Numerical

705

This parameter is expressed in Hertz (s-1).

It declares the line rate, which is the repetition frequency of the video lines scanned and delivered by the camera feeding the channel.

This value is a performance figure often stated as is by the camera manufacturer.

For area-scan cameras, the line rate is usually under control of the camera itself.

In the special case of an area-scan camera receiving horizontal drive information from the frame grabber, the LineRate_Hz parameter expresses the recommended horizontal frequency to be applied to the camera.

For line-scan cameras, the line rate is usually under control of the frame grabber. In that case, the LineRate_Hz parameter declares the maximum line frequency the camera can accept.

In the special case of a line-scan camera controlling its own line timing, the LineRate_Hz parameter expresses the actual horizontal frequency set by the camera.

Values applicable to Grablink Full, Grablink Full XR, Grablink DualBase, Grablink Base

10 to 100000 Hz