Picolo | Picolo Junior 4 | Picolo Pro 2 | Picolo Pro 3 | Picolo Tetra | Picolo Tymo | Picolo Alert | Picolo Diligent |
Domino Iota | Domino Alpha 2 | Domino Melody | Domino Harmony | Domino Symphony |
Grablink Value | Grablink Expert 2 | Grablink Avenue | Grablink Express | Grablink Quickpack ColorScan | Grablink Quickpack CFA | Grablink Full XR | Grablink Full | Grablink DualBase | Grablink Base |
Description
Type |
Integer |
Description |
Minimum delay between successive read-out phases |
"Set" effect |
Sets the minimum delay |
"Get" effect |
Returns the minimum delay |
Classification
Class |
Channel |
Category |
Camera Timing |
Level |
Expert |
Identifiers
String |
ReadoutRecovery_us |
C, C++ |
MC_ReadoutRecovery_us |
.NET |
MC.ReadoutRecovery_us |
Numerical |
1312 |
This parameter is expressed in microseconds (10-6 s). The value is strictly positive.
This is applicable to area-scan cameras only.
It declares the minimum amount of time required by the camera between successive read-out phases.
Values applicable to Grablink Express, Grablink Full, Grablink Full XR, Grablink DualBase, Grablink Base
1 to 1000000 µs