MultiCam Boards Documentation > MultiCam Documentation > MultiCam Reference > Channel Class > Acquisition Control Category > Adjust Level (Acquisition Control) > SeqLength_Ln

SeqLength_Ln

Picolo Picolo Junior 4 Picolo Pro 2 Picolo Pro 3 Picolo Tetra Picolo Tymo Picolo Alert Picolo Diligent
Domino Iota Domino Alpha 2 Domino Melody Domino Harmony Domino Symphony
Grablink Quickpack CFA

Description

Type

Integer

Description

Control of the sequence length by line count

"Set" effect

Sets the number of acquired lines in a sequence

"Get" effect

Returns the currently selected number of acquired lines in a sequence

Classification

Class

Channel

Category

Acquisition Control

Level

Adjust

Identifiers

String

SeqLength_Ln

C, C++

MC_SeqLength_Ln

.NET

MC.SeqLength_Ln

Numerical

3401

The SeqLength_Ln parameter establishes the number of lines to be acquired in a sequence.

The user is invited to set this parameter when EndTrigMode is AUTO and AcquisitionMode has one of the following values: WEB or LONGPAGE.

Setting SeqLength_Ln to MC_INDETERMINATE results in indefinitely repeated page acquisition. A user break is required to terminate the sequence.

Refer to the MultiCam Acquisition Principles application note.

Possible values

Boards

AcquisitionMode

SeqLength_Ln

Grablink series

WEB

MC_INDETERMINATE
[1..PageLength_Ln 65535]

LONGPAGE

[1..PageLength_Ln 65535]