Picolo | Picolo Junior 4 | Picolo Pro 2 | Picolo Pro 3 | Picolo Tetra | Picolo Tymo | Picolo Alert | Picolo Diligent |
Domino Iota | Domino Alpha 2 | Domino Melody | Domino Harmony | Domino Symphony |
Grablink Value | Grablink Expert 2 | Grablink Avenue | Grablink Express | Grablink Quickpack ColorScan | Grablink Quickpack CFA | Grablink Full XR | Grablink Full | Grablink DualBase | Grablink Base |
Description
Type |
Integer |
Description |
Programmable line-scan period |
"Set" effect |
Sets the line-scan period |
"Get" effect |
Returns the currently involved line-scan period |
Classification
Class |
Channel |
Category |
Encoder Control |
Level |
Adjust |
Identifiers
String |
Period_us |
C, C++ |
MC_Period_us |
.NET |
MC.Period_us |
Numerical |
1329 |
This parameter is expressed in microseconds (10-6 s).
It applies when LineRateMode is set to PERIOD.
It allows for programming the periodic generator issuing the downweb line rate in line-scan systems.
Values applicable to Grablink Avenue, Grablink Express, Grablink Full, Grablink Full XR, Grablink DualBase, Grablink Base
1 to 1000000 µs