MultiCam Boards Documentation > MultiCam Documentation > MultiCam User Guide > General Topics > Line-Scan Inspection Topics > Line Frequency Limits > Duration of the Readout Process

Duration of the Readout Process

The readout process lasts a predictable amount of time depending on the pixel frequency and the number of pixels.

Coming back to our representative application, consider that the 2048 pixels are read out of the sensor at a speed of 4 MHz.

The readout duration is 512 µs in this case.