MultiCam Boards Documentation > MultiCam Documentation > MultiCam User Guide > The Channel Class > Understanding Camera Specification > Camera Upstream Specification > Line-Scan Cameras Upstream Specification > Line-Scan, Triggered
Line-Scan, Triggered
Parameter
Value
Meaning
Expose
PLSTRG
The line exposure condition starts upon receiving a pulse from a frame grabber issued signal.
Readout
INTCTL
The line readout condition is totally controlled by the camera.