Stopping the Acquisition Sequence
Manual sequence stop
The Page acquisition sequence stops by setting ChannelState=IDLE.
Two flavors are selectable with parameter BreakEffect:
When BreakEffect=FINISH, the Page acquisition sequence stops after normal completion of the current Page acquisition phase if the Object scanning is already started. Otherwise the Page acquisition sequence stops immediately.
When BreakEffect=ABORT, the Page acquisition sequence stops immediately, interrupting also a Page acquisition phase in progress. The last object acquisition is not usable.
Automatic sequence stop
An automatic sequence stop is available if following conditions are satisfied:
- Number of objects is known before starting the sequence.
- Number of objects is smaller than 65,534.
Therefore, use parameter SeqLength_Fr to specify the number of objects to be acquired. The sequence will automatically stops after SeqLength_Fr phases.