MultiCam Boards Documentation > MultiCam Documentation > MultiCam Reference > Channel Class > Grabber Configuration Category > Expert Level (Grabber Configuration) > PoCL_Status

PoCL_Status

Picolo Picolo Junior 4 Picolo Pro 2 Picolo Pro 3 Picolo Tetra Picolo Tymo Picolo Alert Picolo Diligent
Domino Iota Domino Alpha 2 Domino Melody Domino Harmony Domino Symphony
Grablink Value Grablink Expert 2 Grablink Avenue Grablink Quickpack ColorScan Grablink Full

Description

Type

Enumerated

Description

PoCL (Power over Camera Link) controller status

"Set" effect

"Get" effect

Returns the PoCL controller status

Classification

Class

Board

Category

Grabber Configuration

Level

Expert

Identifiers

String

PoCL_Status

C, C++

MC_PoCL_Status

.NET

MC.PoCL_Status

Numerical

9941

Possible values

Name

Identifier

Description

NO_CAMERA

MC_PoCL_Status_NO_CAMERA

There is no camera connected.

To be detected, the attached camera must deliver a clock signal on Channel_Link_X.

CONVENTIONAL_CAMERA

MC_PoCL_Status_CONVENTIONAL_CAMERA

The camera connected is either a conventional camera or is connected through a non-PoCL cable.

PoCL_CAMERA

MC_PoCL_Status_PoCL_CAMERA

The camera connected is a PoCL capable camera and it is powered by the frame grabber.

To be detected as a PoCL camera, the camera and the cable must be PoCL-compliant. For dual cable configurations (Medium, Full, 80-bit), the camera is declared PoCL-compliant if at least one of the two PoCL controllers identifies a PoCL-compliant camera/cable combination.