Camera Link Upstream Control

Grablink Quickpack CFA provides 4 upstream control lines named CC1, CC2, CC3 and CC4. The usage of these lines is respectively defined by Channel class parameters of the camera features category, CC1Usage, CC2Usage, CC3Usage, and CC4Usage.

CC<1,2,3,4>Usage

Meaning

Applicable to

SOFT

The camera control line is managed through I/O API of the board object.

All CC<1:4> lines

RESET

The camera control line is driven by the reset signal of the acquisition controller.

All CC<1:4> lines

LOW

The camera control line is driven low.

All CC<1:4> lines

HIGH

The camera control line is driven high.

All CC<1:4> lines