Versatile System Inputs - TRA...TRD
There are four versatile digital non isolated input ports in both external and internal system connectors. The ports are named TRA, TRB, TRC, and TRD.
Versatile System Inputs
The port is extremely versatile and accepts both differential and single-ended signaling methods. Following port configurations are available:
- Single-ended TTL/LVTTL
- Single-ended TTL/LVTTL with Pull Down
- Single-ended TTL/LVTTL with Pull Up
- Single-ended High Voltage with Pull Down
- Differential-ended LVDS
- Differential-ended RS-422/RS-485
- Differential-ended TTL/LVTTL
Each port exposes three pins named respectively TRx+, TRx-, and GND; with x = {A, B, C, D}.
A differential-ended signal is applied across TRx+ and TRx- pins; the "warm wire" of the transmission line transporting the signal TRx has to be connected to the TRx+ pin while the "cold wire" of the transmission line has to be connected to the corresponding TRx- pin. The transmission line is terminated by a 120 Ohms resistor.
A single-ended signal is applied across TRx+ and GND pins; the "warm wire" of the transmission line transporting the signal TRx has to be connected to the TRx+ pin while the "cold wire" of the transmission line has to be connected to any GND pin of the system connectors.
The port provides an automatic port configuration mode. When AUTO mode is enabled, the port determines whether a single-ended or a differential-ended signal is driving the port. When a single-ended signal is detected, the port is configured automatically as single-ended LVTTL/TTL and when a differential-ended signal is detected, the port is configured automatically as differential-ended LVDS.
When other port configurations are required, you need to configure the port manually.
DC Characteristics - Automatic mode
When configured in AUTO mode and a single-ended TTL or LVTTL signal is applied across TRx+ and GND, the following characteristics is measured at the input:
Parameter |
Symbol |
Value |
Units |
Single-ended Vin+ High Threshold |
Vse_th_high |
1.7 |
V |
Single-ended Vin+ Low Threshold |
Vse_th_low |
1.6 |
V |
Single-ended Vin+ Hysteresis |
Vse_hyst |
100 |
mV |
Vin+ Range |
Vse_max |
-10 up to 7 |
V |
Single-ended Vin+ Impedance |
Rse |
High-Z |
|
When configured in AUTO mode and a single-ended TTL and a differential LVDS signal is applied across TRx+ and TRx-, the following characteristics is measured at the input:
Parameter |
Symbol |
Value |
Units |
Differential High Threshold |
Vd_th_high |
100 |
mV |
Differential Low Threshold |
Vd_th_low |
-100 |
mV |
Differential Hysteresis |
Vd_hyst |
100 |
mV |
Vin Range |
Vd_max |
4.7 |
V |
Vin+, Vin- Range |
Vse_max |
-0.7 up tp 4 |
V |
Differential Impedance |
Rd |
120 |
Ω |
Single-ended Vin+, Vin- Impedance |
Rse |
High-Z |
|
DC Characteristics - Single-Ended Signaling modes
When configured in single-ended TTL or LVTTL with pull-down mode, the following characteristics is measured at the input:
Parameter |
Symbol |
Value |
Units |
Single-ended Vin+ High Threshold |
Vse_th_high |
2.0 |
V |
Single-ended Vin+ Low Threshold |
Vse_th_low |
1.9 |
V |
Single-ended Vin+ Hysteresis |
Vse_hyst |
130 |
mV |
Vin+ Range |
Vse_max |
-28 up to 29 |
V |
Single-ended Vin+ Impedance |
Rse_pd |
7 |
kΩ |
When configured in single-ended TTL or LVTTL with pull-up mode, the following characteristics is measured at the input:
Parameter |
Symbol |
Value |
Units |
Single-ended Vin+ High Threshold |
Vse_th_high |
1.3 |
V |
Single-ended Vin+ Low Threshold |
Vse_th_low |
1.1 |
V |
Single-ended Vin+ Hysteresis |
Vse_hyst |
130 |
mV |
Vin+ Range |
Vse_max |
-28 up to 29 |
V |
Single-ended Vin+ Impedance |
Rse_pd |
7 |
kΩ |
When configured in single-ended high voltage with pull-down mode, the following characteristics is measured at the input:
Parameter |
Symbol |
Value |
Units |
Single-ended Vin+ High Threshold |
Vse_th_high |
7.5 |
V |
Single-ended Vin+ Low Threshold |
Vse_th_low |
6 |
V |
Single-ended Vin+ Hysteresis |
Vse_hyst |
400 |
mV |
Vin+ Range |
Vse_max |
-28 up to 29 |
V |
Single-ended Vin+ Impedance |
Rse_pd |
4.5 |
kΩ |
DC Characteristics - Differential signaling modes
When configured in Differential terminated LVDS mode, the following characteristics is measured at the input:
Parameter |
Symbol |
Value |
Units |
Differential High Threshold |
Vd_th_high |
100 |
mV |
Differential Low Threshold |
Vd_th_low |
-100 |
mV |
Differential Hysteresis |
Vd_hyst |
100 |
mV |
DVin+ Range |
Vd_max |
4.7 |
V |
Vin+, Vin- Range |
Vse_max |
-0.7 up to 4 |
V |
Differential Impedance |
Rd |
120 |
Ω |
Single-ended Vin+, Vin- Impedance |
Rse |
High-Z |
|
When configured in Differential terminated RS-485/RS-422 mode, the following characteristics is measured at the input:
Parameter |
Symbol |
Value |
Units |
Differential High Threshold |
Vd_th_high |
200 |
mV |
Differential Low Threshold |
Vd_th_low |
-200 |
mV |
Differential Hysteresis |
Vd_hyst |
200 |
mV |
DVin+ Range |
Vd_max |
5.5 |
V |
Vin+, Vin- Range |
Vse_max |
-12 up to 15 |
V |
Differential Impedance |
Rd |
120 |
Ω |
When configured in Differential terminated LVTTL/TTL mode, the following characteristics is measured at the input:
Parameter |
Symbol |
Value |
Units |
Differential High Threshold |
Vd_th_high |
2.2 |
mV |
Differential Low Threshold |
Vd_th_low |
1.6 |
mV |
Differential Hysteresis |
Vd_hyst |
300 |
mV |
DVin+ Range |
Vd_max |
5.5 |
V |
Vin+, Vin- Range |
Vse_max |
-15 up to 15 |
V |
Differential Impedance |
Rd |
120 |
Ω |
AC Characteristics - All modes
Parameter |
Symbol |
Value |
Units |
Signal Bandwidth |
BW |
5 |