MultiCam Boards Documentation > MultiCam Documentation > MultiCam Reference > Channel Class > Encoder Control Category > Adjust Level (Encoder Control) > RateDivisionFactor

RateDivisionFactor

Picolo Picolo Junior 4 Picolo Pro 2 Picolo Pro 3 Picolo Tetra Picolo Tymo Picolo Alert Picolo Diligent
Domino Iota Domino Alpha 2 Domino Melody Domino Harmony Domino Symphony
Grablink Value Grablink Expert 2 Grablink Avenue Grablink Express Grablink Quickpack ColorScan Grablink Quickpack CFA

Description

Type

Integer

Description

Division factor of the line trigger rate divider

"Set" effect

Sets the division factor of the line trigger rate divider

"Get" effect

Gets the division factor of the line trigger rate divider

Classification

Class

Channel

Category

Encoder Control

Level

Adjust

Identifiers

String

RateDivisionFactor

C, C++

MC_RateDivisionFactor

.NET

MC.RateDivisionFactor

Numerical

10553

The rate divider circuit generates a line trigger signal at a frequency that is an integer fraction 1/N of the frequency of the pulses delivered by the quadrature decoder circuit.

For N consecutive incoming pulses issued by the quadrature decoder circuit, the 1/N rate divider:

The rate divider is initialized at the beginning of every MultiCam acquisition sequence. The first output pulse is produced from the first clock input pulse occurring after the sequence trigger event.

Notice that:

This parameter is relevant when LineRateMode=PULSE.

Possible values

1 (default) to 512