MultiCam Boards Documentation > GRABLINK series Documentation > GRABLINK Full XR Handbook > Functional Specification > Hardware Trigger and EndTrigger Control > Electrical Styles

Electrical Styles

The electrical style of trigger and end trigger lines is defined by TrigCtl and EndTrigCtl respectively. There are two new electrical styles for the input lines:

TrigCtl
EndTrigCtl

Description

ISO

Isolated current loop input compatible with TTL, +12V, + 24V signaling

DIFF

Differential high-speed input compatible with EIA/TIA-422 signaling

The default value is ISO.

The electrical style parameters must be defined before other parameters of the Trigger Control category.