MultiCam Boards Documentation > MultiCam Documentation > MultiCam Reference > Channel Class > Trigger Control Category > Expert Level (Trigger Control) > EndTrigLineIndex

EndTrigLineIndex

Picolo Junior 4 Picolo Diligent
Domino Iota Domino Alpha 2 Domino Melody Domino Harmony Domino Symphony
Grablink Value Grablink Expert 2 Grablink Avenue Grablink Express Grablink Quickpack ColorScan Grablink Quickpack CFA Grablink Full XR Grablink Full Grablink DualBase Grablink Base

Description

Type

Integer

Description

Designation by I/O index of end trigger hardware line from outside system

"Set" effect

Sets the I/O index of the end trigger hardware line

"Get" effect

Returns the I/O index of the currently selected end trigger hardware line

Classification

Class

Channel

Category

Trigger Control

Level

Expert

Identifiers

String

EndTrigLineIndex

C, C++

MC_EndTrigLineIndex

.NET

MC.EndTrigLineIndex

Numerical

3446

It designates the hardware line sensed by the channel and aimed at generating the end trigger event. The hardware line is only involved when EndTrigMode is HARD.

To obtain a list of applicable I/O line index, refer to How to Work With Input/Output Lines?