Picolo | Picolo Junior 4 | Picolo Pro 2 | Picolo Pro 3 | Picolo Tetra | Picolo Tymo | Picolo Alert | Picolo Diligent |
Domino Iota | Domino Alpha 2 | Domino Melody | Domino Harmony | Domino Symphony |
Grablink Value | Grablink Expert 2 | Grablink Avenue | Grablink Express | Grablink Quickpack ColorScan | Grablink Quickpack CFA | Grablink Full XR | Grablink Full | Grablink DualBase | Grablink Base |
Description
Type |
Integer |
Description |
Defining the amount of time increasing beginning of pulse defined by StrobePos |
"Set" effect |
Sets the time delay before pulse defined by StrobePos |
"Get" effect |
Returns the currently selected time delay |
Classification
Class |
Channel |
Category |
Strobe Control |
Level |
Expert |
Identifiers
String |
PreStrobe_us |
C, C++ |
MC_PreStrobe_us |
.NET |
MC.PreStrobe_us |
Numerical |
2190 |
This parameter declares the delay of the beginning of the strobe pulse before the normal beginning defined by StrobePos. If long enough, it creates a pre-exposure phase before actual start of exposure phase (SAP).
Its value must be defined in microseconds (10-6 s). It may range from 0 up to 10 milliseconds.
- For area-scan cameras, the PreStrobe_us parameter relates to the illumination during the frame exposure period.
- For line-scan cameras, this parameter is irrelevant.