Starting the Subsequent Page Acquisition Phase
The trigger source for all subsequent acquisition phases is determined by the Next Start Trigger condition. Usually, the Next start trigger event is the same as the Start Trigger condition. The next trigger condition is defined by parameter NextTrigMode.
The start trigger event will produce after a programmable delay a trigger event. This delay can be used to compensate an advanced trigger delivered by a position detector placed away from the camera field of view. The trigger delay can be specified with parameter PageDelay_Ln.
At trigger event, the object scanning starts effectively; however no "Start of Sequence" signal is reported to the user.