LUT_Method
The user selects the LUT construction method by means of the LUT_Method parameter.
Note. The same LUT definition method applies for all LUT devices belonging to a channel.
Controlling parameters associated with each parametric definition method
LUT_Method |
Applicable parametric LUT building control parameters |
RESPONSE_CONTROL |
|
EMPHASIS |
|
THRESHOLD |
LUT_SlicingLevel |
All controlling parameters are of the "float collection" type. The dimension of the collection is equal to the number of LUT devices per LUT set. Refer to 1.1.2 for the number of LUT devices per LUT set.
On boards with 1 LUT device per set, such as Domino Melody, the dimension is 1:
Collection member # |
0 |
Associated color component |
Luminance |
On boards with 3 LUT devices per set, such as Grablink Quickpack ColorScan, the dimension is 3:
Collection member # |
0 |
1 |
2 |
Associated color component |
Red |
Green |
Blue |
On boards with 4 LUT devices per set, such as Grablink Quickpack CFA, the dimension is 4:
Collection member # |
0 |
1 |
2 |
3 |
Associated color component |
Red |
Green |
Blue |
Luminance |