Line Selection
The selection of the hardware trigger line is made via TrigLine. The default value of TrigLine is NOM. The NOM value designates a different connector pin according to the TrigCtl value.
Available values of TrigLine according to the selected TrigCtl
TrigCtl |
TrigLine |
Connector: pin name |
LVDS |
NOM or TRA1 |
SYSTEM:TRA1 |
TRA2 |
SYSTEM:TRA2 |
|
TTL |
NOM or IO1 |
SYSTEM:IO1 |
IO2 |
SYSTEM:IO2 |
|
IO3 |
SYSTEM:IO3 |
|
IO4 |
SYSTEM:IO4 |
|
ITTL,I12V |
NOM or ISOA1 |
SYSTEM:ISOA1 |
ISOA2 |
SYSTEM:ISOA2 |