Factory Outputs - OUT1...OUT4
There are 12 Professional Output ports on factory I/O connector.
Factory outputs
Each port has two pins named respectively OUTi-A and OUTi-B; with i = {1, 2…12}.
This output port emulates a potential-free and polarity-free solid-state contact. The contact remains in the open state during board initialization procedure.
DC specifications
Parameter |
Test condition |
Min |
Typ. |
Max |
Units |
Maximum open contact voltage |
- |
|
|
±30 |
V |
Close -Voltage drop |
Iin = 0.1 mA |
|
0.32 |
0.58 |
V |
Iin = 1 mA |
|
0.51 |
0.74 |
V |
|
Iin = 5 mA |
|
0.71 |
0.92 |
V |
|
Iin = 10 mA |
|
1.25 |
1.40 |
V |
|
Iin = 15 mA |
|
3.30 |
3.75 |
V |
|
Open - leakage current |
Vin = 1 V |
|
1 |
|
µA |
Vin = 3.3 V |
|
1.3 |
|
µA |
|
Vin = 5 V |
|
1.5 |
|
µA |
|
Vin = 10 V |
|
2.0 |
|
µA |
|
Vin = 15 V |
|
2.5 |
|
µA |
|
Rise time |
Iin = 0.1 mA |
|
25 |
|
µs |
Fall time |
Iin = 0.1 mA |
|
4 |
|
µs |
Isolation voltage |
|
|
|
500 |
V |