Description
Type |
Enumerated |
Description |
Electrical style of designated line trigger hardware line from outside system |
"Set" effect |
Sets the line trigger hardware line electrical style |
"Get" effect |
Returns the currently chosen line trigger hardware line electrical style |
Classification
Class |
Channel |
Category |
Encoder Control |
Level |
Adjust |
Identifiers
String |
LineTrigCtl |
C, C++ |
MC_LineTrigCtl |
.NET |
MC.LineTrigCtl |
Numerical |
1331 |
This parameter applies to the hardware line designated by LineTrigLine when LineRateMode is set to PULSE or CONVERT.
Along with LineTrigEdge and LineTrigFilter, it declares the grabber attributes of the terminal sensing the line trigger pulse. The line trigger pulse is processed by the grabber and transferred to the camera as the line reset pulse.
The LineTrigCtl parameter determines the electrical style of the line trigger pulse usually issued by a motion encoder.
Values applicable to Grablink Avenue, Grablink Express
Name |
Identifier |
Description |
TTL |
MC_LineTrigCtl_TTL |
The trigger line is TTL compliant with a 4700 Ω pull-up resistor. |
ITTL |
MC_LineTrigCtl_ITTL |
The trigger line is isolated and TTL compliant with a 3000 Ω pull-up resistor. |
I12V |
MC_LineTrigCtl_I12V |
The trigger line is isolated and 12 V-logic compliant with a 2000 Ω pull-down resistor. |
LVDS |
MC_LineTrigCtl_LVDS |
The trigger line is differential LVDS, RS-422 or RS-485 compatible. |
Values applicable to Grablink Value, Grablink Expert 2, Grablink Quickpack ColorScan
Name |
Identifier |
Description |
TTL |
MC_LineTrigCtl_TTL |
The trigger line is TTL compliant with a 4700 Ω pull-up resistor. |
ITTL |
MC_LineTrigCtl_ITTL |
The trigger line is isolated and TTL compliant with a 3000 Ω pull-up resistor. |
I12V |
MC_LineTrigCtl_I12V |
The trigger line is isolated and 12 V-logic compliant with a 2000 Ω pull-down resistor. |
Values applicable to Grablink Full, Grablink Full XR, Grablink DualBase, Grablink Base
Name |
Identifier |
Description |
DIFF |
MC_LineTrigCtl_DIFF |
Differential high-speed input compatible with EIA/TIA-422 signaling. |
DIFF_PAIRED |
MC_LineTrigCtl_DIFF_PAIRED |
Dual differential high-speed input compatible with EIA/TIA-422 signaling. Default value. |
ISO |
MC_LineTrigCtl_ISO |
Isolated current loop input compatible with TTL, +12V, +24V signaling. |
ISO_PAIRED |
MC_LineTrigCtl_ISO_PAIRED |
Dual isolated current loop input compatible with TTL, +12V, +24V signaling. |