MultiCam Boards Documentation > MultiCam Documentation > MultiCam Reference > Channel Class > Encoder Control Category > Adjust Level (Encoder Control) > LineTrigFilter

LineTrigFilter

Picolo Picolo Junior 4 Picolo Pro 2 Picolo Pro 3 Picolo Tetra Picolo Tymo Picolo Alert Picolo Diligent
Domino Iota Domino Alpha 2 Domino Melody Domino Harmony Domino Symphony
Grablink Quickpack CFA

Description

Type

Enumerated

Description

Noise removal on designated line trigger hardware line from outside system

"Set" effect

Sets the line trigger hardware line cleaning mode

"Get" effect

Returns the currently chosen line trigger hardware line cleaning mode

Classification

Class

Channel

Category

Encoder Control

Level

Adjust

Identifiers

String

LineTrigFilter

C, C++

MC_LineTrigFilter

.NET

MC.LineTrigFilter

Numerical

1333

This parameter applies to the hardware line designated by LineTrigLine when LineRateMode is set to PULSE or CONVERT.

Along with LineTrigCtl and LineTrigEdge, it declares the grabber attributes of the terminal sensing the line trigger pulse. The line trigger pulse is processed by the grabber and transferred to the camera as the line reset pulse.

The LineTrigFilter parameter reduces the noise sensitivity over the line trigger pulse usually issued by a motion encoder.

The time constant of the filter is the amount of time the line should be detected at the same logic state before a logic transition be considered.

When LineTrigLine is an insulated I/O, LineTrigFilter is forced to STRONG.

Values applicable to Grablink Full, Grablink Full XR, Grablink DualBase, Grablink Base

Name

Identifier

Description

OFF

MC_LineTrigFilter_OFF

The filter time constant is approximately 40 ns.

MEDIUM

MC_LineTrigFilter_MEDIUM

The filter time constant is approximately 100 ns. Default value.

STRONG

MC_LineTrigFilter_STRONG

The filter time constant is approximately 5 µs.

Filter_40ns

MC_LineTrigFilter_40ns

The filter time constant is approximately 40 ns.

Filter_100ns

MC_LineTrigFilter_100ns

The filter time constant is approximately 100 ns.

Filter_200ns

MC_LineTrigFilter_200ns

The filter time constant is approximately 200 ns.

Filter_500ns

MC_LineTrigFilter_500ns

The filter time constant is approximately 500 ns.

Filter_1us

MC_LineTrigFilter_1us

The filter time constant is approximately 1 µs.

Filter_5us

MC_LineTrigFilter_5us

The filter time constant is approximately 5 µs.

Filter_10us

MC_LineTrigFilter_10us

The filter time constant is approximately 10 µs.

Values applicable to other Grablink boards

Name

Identifier

Description

OFF

MC_LineTrigFilter_OFF

The filter time constant is approximately 100 ns.

MEDIUM

MC_LineTrigFilter_MEDIUM

The filter time constant is approximately 500 ns.

STRONG

MC_LineTrigFilter_STRONG

The filter time constant is approximately 2500 ns.