MultiCam Boards Documentation > MultiCam Documentation > MultiCam User Guide > The Channel Class > MultiCam Triggering > Grabber Triggering Mode > Grabber Triggering Examples > Triggering Example 7

Triggering Example 7

Armed multiple-phase
Area-scan, asynchronous reset
Without phase overlapping

This triggering modality is reached when the following combination of parameters is set:

MultiCam parameter

Value

ExposeOverlap

FORBID

TrigMode

HARD
SOFT
COMBINED

NextTrigMode

HARD
SOFT
COMBINED

SeqLength_Fr

MC_INDETERMINATE, >1

This example shows the way to grab several successive images from an asynchronously reset camera using an external frame trigger.

All trigger events (TE) are sourced by a hardware- or software-issued event. There is no substantial delay between the source and SAP events.

Use this triggering mode with TrigMode and NextTrigMode set to SOFT for software-controlled grabs if a tight timing is to be met.

Specify the number of images to be acquired in a row with the parameter SeqLength_Fr. To acquire an undefined number of images, set SeqLength_Fr to MC_INDETERMINATE. In this case, the sequence will be stopped by returning the MultiCam channel to the idle state.