MultiCam Boards Documentation > PICOLO series Documentation > MIO Module Handbook > System Integration > I/O SCREW TERMINAL Connector > Output Thresholds

Output Thresholds

The four outputs are electromagnetic dry-contact reed relays. So electrical isolation from the PC case potential and from other outputs is assured.

Each output is represented by two terminals named OnA and OnB, where n is 1, 2, 3 or 4.

An output is active when OnA is connected to OnB (dry-contact short). In these conditions, a current of 1 A maximum can flow, in any direction, through the contact.

An output is inactive when OnA and OnB are not connected (dry-contact open). In these conditions, a voltage of 200 V maximum can be established between the terminals.

The output state is displayed with 4 orange LEDs: a LED is lighted when the corresponding output is active.

The output 4 of the MIO Module can be associated with a timer in order to be used as alarm or watchdog. At start up, this association is done, unless AlarmConfig or WatchDogConfig is DISABLE.

Parameter

Maximum value

Switched current

0.5 A

Switched voltage

200 V

Switched power

10 W

Note. The product of the switched current and the switched voltage cannot be greater than the switched power.