MultiCam Boards Documentation > GRABLINK series Documentation > GRABLINK Base Handbook > Functional Specification > Line Triggering > Line Trigger, Line Selection

Line Trigger, Line Selection

When LineRateMode is PULSE or CONVERT, the line trigger signal originates from an external motion encoder device. In that case line trigger input port(s) must be selected.

The selection is performed in two steps:

LineTrigCtl

Description

Targeted type of motion encoder device

DIFF

Single differential high-speed input port compatible with EIA/TIA-422 signaling

Single output RS-422 compatible incremental motion encoder

DIFF_PAIRED

Pair of differential high-speed input ports compatible with EIA/TIA-422 signaling. Default value.

Dual-output RS-422 compatible phase quadrature incremental motion encoder

ISO

Single isolated current loop input port compatible with TTL, +12V, + 24V signaling

Single output incremental motion encoder

ISO_PAIRED

Pair of isolated current loop input ports compatible with TTL, +12V, + 24V signaling

Dual-output phase quadrature incremental motion encoder

LineTrigCtl

Default port(s) assignment

Alternate port assignment(s)

DIFF

DIN1

DIN2

DIFF_PAIRED

DIN1 (A) + DIN2 (B)

-

ISO

IIN1

IIN2
IIN3
IIN4

ISO_PAIRED

IIN1 (A) + IIN2 (B)

IIN3 (A) + IIN4 (B)

Notes