Triggering Example 2

Immediate single-phase
Area-scan, asynchronous reset
Without phase overlapping

This triggering modality is reached when the following combination of parameters is set:

MultiCam parameter

Value

ExposeOverlap

FORBID

TrigMode

IMMEDIATE

NextTrigMode

Irrelevant

SeqLength_Fr

1

This example shows the simplest software-controlled way to grab an image from an asynchronously reset camera.