Triggering Example 3
Armed single-phase
Area-scan, asynchronous reset
Without phase overlapping
This triggering modality is reached when the following combination of parameters is set:
MultiCam parameter |
Value |
FORBID |
|
HARD |
|
Irrelevant |
|
1 |
This example shows the way to grab an image from an asynchronously reset camera using an external frame trigger.
The trigger event (TE) is sourced by a hardware- or software-issued event. There is no substantial delay between the source and SAP events.